0. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. NI-DAQmx. NI ETS 2009부터 NI는 ETS OS를 지칭할 때 OS 버전 대신 LabVIEW 릴리스 번호를 사용하기 시작했습니다. National Instruments cRIO-9035 CompactRIO Controller- 1 GB DRAM, 4 GB. cRIO-9024 cRIO-9025. . NI CompactRIO 디바이스 드라이버. I acctually have the cRIO 9024 and LabVIEW. However, you still need to make sure that the Xilinx Compilation Tools supports your device. Bei Fragen dazu, welche Versionen der Software mit bestimmten Gerätemodellen zusammenarbeiten, lesen Sie bitte den Abschnitt Unterstützte Hardware. All Manuals. NI R 시리즈 다기능 RIO 디바이스 드라이버. The problem is whenever I start my cRIO-9072, I have to undeploy all my digital modules and redeploy it again in order for it to detect the digital output modules. Using incompatible versions may result in errors, the. EtherCAT is an Ethernet-based deterministic synchronized protocol. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. This article aims to document how National Instruments’ benchmarks NI. This should be under Remote Systems. Here is the scenario. Real-Timeコントローラ: cRIO-9022、cRIO-9023、cRIO-9024、およびcRIO-9025; CompactRIO再構成可能シャーシ: cRIO-9111、cRIO-9112、cRIO-9113、cRIO-9114、cRIO-9116、およびcRIO-9118; 統合型CompactRIO Real-Timeコントローラ:. xx. After selecting a static IP address, reboot the cRIO to confirm the new settings. Built a custom device in asynchronous execution mode . USB Port 5. The "ERR" LED on the cRIO 9144 does not turn on. Team, many thanks in advance for your support. Options. The cRIO-9024 filters and regulates the supplied power and provides power for the C Series modules. . Usually, some combination of rebooting the cRIO, rebooting the VM, enabling and disabling the virtual and real network adapters will eventually result in clearing the "Inconsistent IP Settings" state. How can I synchronize the 9024 rack and the 9068 rack? I have NI-TimeSync 1. This rugged, fanless controller features a variety of. I tried CompactRIO driver v17. The Software installation is probably corrupted: Right Click > Delete the cRIO in NI MAX and add it again. cRIO-9101 cRIO-9102 cRIO-9103 cRIO-9104 cRIO-9111 cRIO-9112 cRIO-9113 cRIO-9114 cRIO-9116 cRIO-9118. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator; Hello, I am started to learn Labview and i want to communicate with CANopen (9881) module in FPGA interface,. Reboot the device. Beyond jitter, note that you will be able to see a substantial performance improvements in loop rates with the NI Linux Real-Time based cRIO-9068 over the cRIO-9024 and cRIO-9074 controllers and with the cRIO-903x controllers over the previous generation cRIO-9025. xx. The controller I am using is CompactRIO NI cRIO-9024. Aerospace, Defense, & Government. USB Retention StandoffNI CompactRIO and Drivers Drops Support for Windows 7 (32- and 64-Bit), Windows Server 2008 R2, and All 32-Bit Windows Operating Systems in 2021. CompactRIO cRIO-9012/9014 このドキュメントでは、NI cRIO-9012/9014リアルタイム組込コントローラをネット ワークに接続する方法と、コントローラの機能の使用方法を説明してい. x. When I choose the excitation voltage to be 2. National Instruments cRIO-9024 CompactRIO Controller- 512 MB DRAM, 4 GB Storage. 0. Using incompatible versions may result in errors, or missing palettes or functions. Use a switch to suppl. The cRIO-9030 requires a 9 V to 30 V external power supply. Restart the computer, then connect the device's power cable. National Instruments NI cRIO-9024 User Manual And Specifications (21 pages) Intelligent Real-Time Embedded Controller for CompactRIO. Team, many thanks in advance for your support. ネットワーク経由でホストコンピュータに接続するCompactRIO(cRIO)または産業用コントローラ(IC)デバイスがあり、次のいずれかが発生しています。 Measurement&Automation Explorer(MAX)でデバイスを設定しようとしていますが、リモートシステムの下にデバイスが表示されません。The cRIO-9034 is a rugged, fanless, embedded controller that you can use for advanced control and monitoring applications. LabVIEW Real-Time 모듈. k-waris. However, you still need to make sure that the Xilinx Compilation Tools supports your device. The cRIO-9012/9014 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO Certificate No. My LabVIEW version is 2015 and. 65 MB. I have a cRIO 9024 controlelr on a 9114 chassis with digital output module NI 9401. 5. 0 Kudos Message 4 of 12 (3,721 Views) Reply. 1 . zip". The NI cRIO-9075 supposes a more economical solution but it has lower processing capabilities than the NI cRIO-9024, which prevents the registering of some events such as rapid voltage changes or unbalance factors. It is designed to easily interface with more than 85 Quanser controls experiments. ( stand alone without a host computer) The CompactRio is connected to a network drive( like \\\\XXX. Figure 17 NI cRIO-9024 real-time controller, from [22]. Please. Side mounting kits are capable of panel/wall mount and DIN-rail mount. I also wanted to point out that the Xilinx tools have nothing to do with the difference between the cRIO-9004 and the cRIO-9024. The embedded user interface capability and Mini DisplayPort let you add a local human. I have set-up the IP address for the cRIO which is 10. My purpose is to supply the pt100 a current 0 to 20mA to study its characteristics. cRIO-9024. 03-24-2014 09:25 AM - edited 03-24-2014 09:26 AM. I modified an example that will take the data, but it does not log (having issues with that, too) and stops working once communication is lost (9205IO attached). I have a Beckhoff C6015-0010 (with C9900-C583). The ultrasonic ranger is srf05. The convenient Q1-cRIO set of I/O and connectors minimizes setup time and errors so students can concentrate on learning the fundamentals of controls. My real time controller is a NI cRIO-9024 with a NI 9114 chassis connected to it. 08-28-2014 08:22 PM. CompactRIO real-time controllers enable you to directly deploy your control algorithm and run the code National Instruments cRIO-9024 CompactRIO Controller. 0089X certified. The controller provides. I installed NI Real-Time Desktop PC in this. 見積もりのお申込み 最適な製品の選択 製品のご注文 製. LEDs 6. View listing photos, review sales history, and use our detailed real estate filters to find the perfect place. This small feature would add convenience on the cRIO-903x series controllers. The cRIO‑9024 does not include. It includes a Kintex-7 70T FPGA with LabVIEW FPGA Module support for advanced control and coprocessing. To. It show only cRIO 9024 which is the main device and cRIO-9144 which is show in device and interfaces tab. The included device driver communicates with the firmware to help you set up and control how the compatible. -1 x cRio 9024 (1 x 9239; 4 x 9233)-6 x sbRIO 9267 (7 x 9205)-1 x 6221 with a lower sample rate. xx is the IP address of the Compact RIO. I am trying to make a simple VI that will read in a CAN signal and write to a TDMS file. I'm using a CRio 9024 that has 2 NI 9263s, an NI 9472, NI 9205, and 3 NI 9485s installed as well as the 9862. Supplied with the Quanser Rapid Control Prototyping (RCP) Toolkit®) 3. ATE and Labview Consultant. Phone number: 1-877-854-3577 — Email: CEC@ul. The article I linked links on to the page you've linked, and I think I've followed that article correctly. This is explained in the 'How to Get Started With the Power Monitoring Starter Kit for NI CompactRIO". I would like to use the NI cRIO-9045. 0, v18. I am using cRIO-9024 with a 9112 chassis to control a system. 향상된 기능 및 CAR 수정 사항이 2009년부터 NI ETS에 지속적으로. 2. CompactRIO cRIO-9074XT NI cRIO-907x 1 3 5 2 4 6 7 8 POWER FPGA STATUS USER1 TE CABLES WHEN TIONS SAFE MODE CONSOLE OUT IP RESET NO APP USER1 NO FPGA LINK LINK 10/ 100 10/ 100 RESET INPUT. Options. For example, I want to generate a 10-us delay. This article aims to document how National Instruments’ benchmarks NI. A valid service agreement may be required. Re: Problems connecting to cRIO-9024 in MAX. Special Conditions for Hazardous Locations Use in Europe and Internationally. The cRIO-9002/9004 draws power from the power source MAX lists the cRIO controller as the model name of the controller followed by the MAC address, for example, NI-cRIO-907400802f10856. A valid service agreement may be required. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. I have a cRIO 9073 connected to a PC via a crossover cable. 0. Hello all, I have a Sick lms 100 laser scanner connected to the one of the 2 TCP/IP ports of a CRIO 9024 and wanna get data from the Sick. 10-18-2017 11:53 AM. 6, CompactRIO real-time controllers using the VxWorks operating system can be configured to synchronize to SNTP servers. MODULE ASSY,CRIO-9024,POWER PC BASED EMBEDDED CONTROLLER FOR COMPACTRIO. I would like to ask if someone can recommend some of the model/brand I should purchase - I am new. I would like to save measured data from modules into the txt files but I would like to do it in some time period for desire time. To restore my CompactRIO (cRIO), sbRIO, PXI Real-Time controller, stand-alone USRP controller, or other real-time targets to factory default. Software installed in my cRIO is NI CompactRIO 14. I have cRIO 9024 along with chassis. Solution. 0. 1, LabVIEW Real-Time 15. Options. コントローラからWindowsマシンにni-rt. Table 2. However, there's not a repeatable set of. 変更したni-rt. Chassis cRIO 9113. If a configure the custom device with no modules their is no problem to deploy to the cRIO. cRIO-9012およびcRIO-9014コントローラのサポートが削除されました。. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. 10-09-2018 05:56 PM. Page 5 Ethernet, NI recommends using a CAT-5 or better shielded twisted-pair. Re: issue with connecting with CompactRio 9024. Safety Guidelines for Hazardous Locations. I have a NI 9264 analog output that is connected to a current control board and a NI 9234 analog input installed on a cRIO-9024. Go to the Device Manager, try to find an item that contains the serial number of your device such as «USBVID_3923&PID_762FXXXXXXXX» where XXXXXXXX is a serial number of your device. out) on cRIO-9024 which is VxWork. I want to synchronize this master time reference with the RT System Time on a cRIO-9024 controller (slave). I would like to get access to the interactive test panel, but whenever i try to do this it won't let me deploy the unit. It runs the NI Linux Real-Time operating system with access to the I/O through NI-DAQmx drivers or with the LabVIEW FPGA module. . cRIO-9024 Serial VISA Bug. slot 3 = NI-9263. With thearinc & 1553 . LabVIEW FPGA模块 (仅当您想直接对FPGA进行编程时才需要). txt), i have to have all this data avaiable in the HOST so i can parse them to the FPGA according to its "demand". Figure 2. My cRIO is configured to allow TCP/IP protocol, The VI is visible, and I have made my project into a source distribution on my. Let me explain what I have done. CRIO | 9,024 followers on LinkedIn. 3 V or 5 V in properties menu, I can read the exact voltage values from pin 6 and 7 by using multimeter. you have to install the NI RIO driver on you cRIO (but first in your PC). If you're unable to see the serial port, ensure that the correct version of the driver is installed. LabVIEW NXG. 解决方案. A custom. NI is now part of Emerson. Thus, NI-9881 is not supported when used in cRIO-910x or cRIO-907x reconfigurable chassis but only in cRIO-911x chassis or in cRIO-903x, 904x, 905x, 906x and 908x. The FPGA Interface C API is a C API for communication between processor and FPGA within NI reconfigurable I/O (RIO) hardware such as NI CompactRIO, NI Single-Board RIO, NI Ethernet RIO, NI FlexRIO, NI R Series multifunction RIO, and NI MXI-Express RIO for embedded control and acquisition applications. Thank you for your usual support. Note: NI will remove support for Phar Lap for cRIO in the NI 2020 Software Release and for PXI in the NI 2022 Software Release. Sorry about that, should have scoured the doc. g. Figure 1. 6. arinc & 1553 . Do you find the way to force the complier to use more of the LUT slices and other slice registers if the DSP48s is full?Hi All, My system is: Labview 2014 SP1 NI cRIO-9024 Controller NI-9264 Scan Mode . I have some questions: 1) I cannot see the examples because Labview 2009 shows that The NI Service locator is not running. But there are easier (but more expensive) ways to switch a button. It offers Intel Atom dual-core processing, an Artix-7 FPGA, and eight slots for C Series modules. 2. Any idea why this is happening? Overcurrent? Thanks! 0 Kudos Message 1 of 2 (2,121 Views) Reply. EtherCAT is an Ethernet-based deterministic synchronized protocol. The newest version is 3. The Quanser Q1-cRIO is a C Series module for the NI cRIO-9024 controller and NI cRIO-9113 backplane. Looking for a correlation between Xilinx tools and those models numbers would be non-existent, and that probably increased your frustration. I am currently connecting to an RT cRIO 9024 and I am having the same problem. After that compiled VxWorks engine into the custom device in order to run on VxWorks OS,. e. I have a 9204 cRIO with all eight chassis modules full (1x serial and 7x 4-20mA input). If DHCP is not available, the controller connects to the network with a link-local IP address with the form 169. 255. 맨. The cRIO‑9025 does not include. I am working with a cRIO-9024 chassis with a 9870 card also attached for additional serial ports, bringing my total available up to 5. 255. NI-Serial for LabVIEW Real-Time, Version 3. The NI cRIO-9024 rugged, reliable controller is designed for low-power consumption with dual 9 to 35 VDC supply inputs that deliver isolated power to the CompactRIO chassis/modules and a -20 to 55 °C operating temperature range. If you are in home network which has DHCP server ,reset your IP using Hardware switch and restart your system. Provides support for NI data acquisition and signal conditioning devices. Hello I am new to real time acqusition and I am using cRIO 9024 with NI 9219 NI 9225 and NI 9215 for my data acqisition. Additional you can find the UART 8N1 Simulation. All Manuals. You can find some. Rated 0 /5 based on 0 ratings. The included device driver communicates with the firmware to help you set up and control how the compatible CompactRIO. 3. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed;. The Quanser Q1-cRIO is a C Series module for the NI cRIO-9024 controller and NI cRIO-9113 backplane. 2. With the FPGA Interface C API,. 자세한 내용은 Phar Lap RT OS EOL 로드맵을 참조하십시오. 5. Pop up window appears to either discover 'Existing target or device' or add new target. i connet the cRio-9024, chassis cRio-9114 local ip network and install the ISE 10. Options. The IP address must be on a different subnet than the . but it'sNI cRIO-903xまたはNI cRIO-906xと共にNI Compact RIO 17. Change Modbus TCP/IP master IP address programmatically. All of control system was in FPGA. the other TCP/IP port is obvously connected to the pc. I'm using a CRio 9024 that has 2 NI 9263s, an NI 9472, NI 9205, and 3 NI 9485s installed as well as the 9862. I created a project and ran Host. . RS-232 Serial Port 4. To resolve this issue, work through the troubleshooting steps below: Check that the controller's power supply is working as expected. I am working with a cRIO-9024 chassis with a 9870 card also attached for additional serial ports, bringing my total available up to 5. html directory. 0. We would like to show you a description here but the site won’t allow us. e. 7 Using the LabVIEW test panel (see image below), I'm able to toggle the slave between Boo. 2. The NI cRIO -9024 real -time controller is equipped with a powerful Freescale 800 MHz CPU, 4 GB non - volatile flash memory, and Ethernet, USB and RS -232 interfaces. You also can use the Mini DisplayPort to add a local human machine. As of LabVIEW Real-Time 8. slot 1 = NI-9401. png. 2) cRio application we did PWM regulation programmed on FPGA with a NI-9477 DO module. 0 etc. Options. Solution. I try to analyse the signal to determine the wind speed. slot 2 = NI-9239. How I can solve it? 2) How is the best way to filter measured analogue data?- cRIO-9024 RT-Controller - cRIO-9112 Chassis - C-Series NI9220 (16x100kS/s simultaneous), - 2x C-Series 9221 (2x400kS/s aggregated) and - C-Series 9222 (4x400kS/s simultaneous). All VIs for UART you find in UART 8N1 (FPGA). 2011 SP1. When building the standalone real time application and running it as startup, something stops working. cRIO-904x Firmware and Additional Drivers includes a device driver as well as firmware for the cRIO-9040, cRIO-9041, cRIO-9042, cRIO-9043, cRIO-9045, cRIO-9046, cRIO-9047, cRIO-9048, and cRIO-9049 CompactRIO Controllers. Re: NI 9476 K C. I am using a cRio 9024, and 6 modules for signal input and signal output. White Rabbit on the NI-cRIO The White Rabbit Timing receiver is an open hardware design, available on CERN s open hardware repository. Introduction. Previously, this worked when using LabVIEW 2015 SP1 f10, LabVIEW FPGA Module 15. I'm able to create sine-on-sine (double sine) waveform by using NI 9264. In the end, i wont be. National Instruments provides the NI-Industrial Communications for EtherCAT driver to install a master software stack to several targets including Real-Time Compact RIO, Compact DAQ, and Compact Vision Systems. Either NI-VISA is not installed on this system, or NI-VISA does not support creating new resources on this type of system. Order by Part Number or Request a Quote. (targer searching, debug, deploy)The main system comprised a scrum machine fitted with an NI cRIO-9024 controller. 0, 10. This document describes the range of software versions required for the aforementioned devices and links to the most recent documentation resources available. 0089X certified. I tried now to do this with scan engine but I couldn't find the way to get a PWM output to the 9477. I am new to working with LabVIEW, and I am currently attempting to install software onto a Compact RIO NI-9024 under LabVIEW 8. 9 /5 based on 13 ratings. The host was only responsible of doing some mathematical calculations (counting cycle, last stroke, etc. However, when I manually change the current time on the cRIO 9024, the EtherCAT slave stops working: In the DSM, all of its channel values are completely frozen, while the EtherCAT master's channels still. If we generally use an FPGA clock rate of 40 MHz, the VI is running in the time of 25 nanoseconds. NI technical support confirmed the problem, but mentioned that newer cRIOs with NI Linux RT don't have this issue. FTP the ni-rt. 다른 곳에서는 업데이트가 되는데 제가 태블릿 피씨에서 USB to Ethernet 포트로 장비를 찾아 업데이트를 진행할려고 하면 문제가 발생합니다. Options. Order by Part Number or. To configure the controller to synchronize to an SNTP server, go through the following steps: 1. 2, adds support for the NI 9792 controller. This document will help you achieve the highest measurement quality when using high-power CompactRIO systems that contain a cRIO-9022 or cRIO-9024 controller and/or a cRIO-9111, cRIO-9112, cRIO-9113, cRIO-9114, cRIO-9116, or cRIO-9118 reconfigurable embedded chassis (referred to inclusively as the cRIO-911x). The software is developed in LabVIEW RT 2011. 1. x. 0089X certified. 0. NI CompactRIO을(를) 다운로드하고 지원 정보를 찾으십시오. cRIO-9024 cRIO-9025. Page 4 Using a Phillips #2 screwdriver, tighten the two captive screws on the front of the cRIO-9024 to 1. Guess I need a. Right click Compact RIO Target > New > Target and Devices. Jacob_K. Options. Hello, I have NI cRIO 9024 with NI 9215 and NI 9263. Today, almost every spindle is equipped with sensors to monitor the bearing temperature (T bearing). motion and drives. Find many great new & used options and get the best deals for NI cRIO NI 9024 CompactRIO Controller / 800 MHz CPU, 512 MB DRAM, 4 GB Storage at the best. . If you filled an entire 8 slot chassis with 9215 modules you would use about 12 MB/s. NI-RIO驱动程序. 5. I am using the digital modules to drive some devices. X. If the unconfigured state of the cRIO continues after actively. source. Another option for you would be to reassign the PC #2 network card IP address to something in the range 169. 09-24-2012 12:16 PM. ) of torque. Voltage controlled current Source. In order to run FPGA VIs, you must go to the chassis properties page, select FPGA programming mode, and deploy the settings. The CompactRIO real-time controller (NI cRIO-9024) has an 800 MHz industrial processor that balances low power consumption and powerful real-time control algorithms, signal analysis, and data logging. Depending on the number of slots you need, I would recommend either the cRIO-9064 (4 slots) or the cRIO-9067 (8 slots). 0およびドライバ をインストールしてLabVIEWで使用するには、以下の手順に従ってください。 特定のハードウェアデバイスをサポートするソフトウェアバージョンを確認するには、「サポートされているハードウェアとソフトウェア. GPS is supported on cRIO using a dedicated module which has a synchronization accuracy of 100 ns [8]. The Quanser Q1-cRIO is a C Series module for the NI cRIO-9024 controller and NI cRIO-9113 backplane. DIP. Without knowing anything else about your project, my first thought is that the name of the cRIO changed and thus any variables pointing to it are still looking for the old name. Each cRIO-9024. I want to design a digital signal processing circuit with the following sequence . g. I have also NI cRIO 9024 plus chassis cRIO 9112 and modules. Eventually, the data logger will be used in a hardware in the loop system, another topic I am new to. National Instruments cRIO-9038 CompactRIO Controller- 2 GB DRAM, 8 GB Storage. Zillow has 23383 homes for sale in British Columbia. NI CompactRIO 20. Quanser Q1-cRIO 4. What is the model of the chassis which has the FPGA board? Most likely you are using the old chassis which requires ISE Compilation Tool. Re: Easy Custom device tool - how to get actual waveforms or data from a channel Ryan_K. Real. Sorry for the slow reply. アカウント. Disconnect the device from power and from the computer. CompactRIO Reconfigurable Chassis: NI cRIO-9111, NI cRIO-9112, NI cRIO-9113, NI cRIO-9114, cRIO-9116, and cRIO-9118. Provides support for NI. Open NI Measurement & Automation Explorer (MAX) and find your cRIO. 254. 255. N/A: 2. Engineers at the University of Zürich have used the WR design to build a C-series module for the cRIO platform, The cRIO-9024 filters and regulates the supplied power and provides power for the C Series modules. cRIO-9024 Product Certifications. This project is configured to work on cRIO-9024 with NI 9118 backplane and NI 9401 DIO module. Part Number: cRIO-9024: Manufacturer/Brand: Equipment: Description: National Instruments 781174-01 CompactRIO Controller Legacy: Speak to a sales representative for pricing & lead time: Phone:This document will help you achieve the highest measurement quality when using high-power CompactRIO systems that contain a cRIO-9022 or cRIO-9024 controller and/or a cRIO-9111, cRIO-9112, cRIO-9113, cRIO-9114, cRIO-9116, or cRIO-9118 reconfigurable embedded chassis (referred to inclusively as the cRIO-911x). The data is transferred across a PCI bus which can transfer 133MB/s. On the other hand, you can definitely control discrete power supplies with LabVIEW (and the cRIO-9024). 現在、NI cRIO-9024とNI9401、LabVIEW2014を使って、任意の周波数のデジタルパルスを生成するプログラムを作成しています。 サンプルプログラムの PWM Generation. Use this guide to select the correct MXI-Express cable for your CompactRIO Controller. However, there seems to be a synchronization issue that can be. National Instruments provides the NI-Industrial Communications for EtherCAT driver to install a master software stack to several targets including Real-Time Compact RIO, Compact DAQ, and Compact Vision Systems. Note The NI-XNET software supports only National Instruments CAN, FlexRay, and LIN hardware products. 0 etc. I'm having trouble setting up a cRIO-9024 and a CRIO-9014 (not at the same time) with the latest versions of Labview and Windows 10. For. The hardware I'm using is NI cRIO-9076 but I have the same problem with a cRIO 9024 + chassis cRIO 9114. These a. I'm surprised by the cRIO executable starting time after reboot. Expand Remote Systems in the left menu to find your cRIO. NI cRIO-9063 NI cRIO-9068 NI cRIO-9024 with NI cRIO-9113 or NI cRIO-9114 Chassis NI cRIO-9074 PC or PXI running 32 or 64-bit Microsoft Window 7, Windows 8. 03-08-2014 10:33 PM. The cRIO-9024 filters and regulates the supplied power and provides power for the C Series modules. " LabVIEW: (Hex 0x80DF001E) The deployment. Hi, all . 02-18-2010 05:24 PM. 1. HenrikUlfhielm. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Hello, I have Labview 2009, Labview Real-Time 2009 and cRIO 3. The screenshot above is a modification. Hello Ali_H, I am using labview 2013 with RIO0-7851R, and I met the same problem, that is the code is eating the DSP48s but keeping the slice LUT and registers at low consumption. Member. 0. You must connect Ethernet port 1 to configure the cRIO-9024. I’m having a problem reading all the CAN signal into my LV vi through an XNET session on a NI 9862 cRIO module. Hi Cashany, you surely can read that switch status. 2011 SP1. ini file from the controller to your Windows machine. Dimensions The following figure shows the cRIO-9024 dimensions. Member. You can program the chassis using Scan Mode for fast expansion of your real-time system or using the onboard FPGA for inline processing and high. This article explains how to restore a LabVIEW Real-Time device to the factory default configuration. Whether you are creating a new configuration, replacing or expanding your current CompactRIO System, or verifying that existing parts can be used in a different configuration. lvproj に少しだけ手を加えただけではありますが、添付画像のような、指定した時間だけONの状態で待機し、その後同じ時間だけOFFの状態で. cRIO-9024 + NI 9113 Chassis + NI 9881 (CANopen) FPGA Compile Problem batuypn.